Opened 8 years ago

Closed 8 years ago

#909 closed defect (fixed)

Units on SLD need fixing for some models

Reported by: butler Owned by: krzywon
Priority: critical Milestone: sasmodels 1.0
Component: SasView Keywords:
Cc: Work Package: SasView Bug Fixing

Description (last modified by butler)

In 4.0 the units of SLD were changed from 1/Ang2 to 1e-6/Ang2. Somehow a few models did not get the displayed units right. In particular, for Hollow Cylinder the UI displays the units as 1/Ang2.

Change History (2)

comment:1 Changed 8 years ago by butler

  • Description modified (diff)
  • Priority changed from blocker to critical
  • Summary changed from Units on SLD need fixing to Units on SLD need fixing for some models

comment:2 Changed 8 years ago by krzywon

  • Owner set to krzywon
  • Resolution set to fixed
  • Status changed from new to closed

In f102a968fd7dd1402f915b8638cd66eaf4375710/sasmodels:

Change units on SLD parameters on hollow cylinder. Grep shows this is the only model that needed changing. Closes #909