Opened 8 years ago
Last modified 7 years ago
#592 new enhancement
linearized models need to account for resolution smearing
Reported by: | butler | Owned by: | |
---|---|---|---|
Priority: | major | Milestone: | SasView 5.0.0 |
Component: | SasView | Keywords: | |
Cc: | Work Package: | Plotting/Graphing Enhancements |
Description
Currently resolution smearing is not accounted for and thus heavily smeared data, such as USANS slit smeared data give totally wrong answers, particularly for I0 which is several orders of magnitude wrong. however even pinhole resolution at medium q can slightly alter the value of Rg.
Also suggest taking the opportunity to ditch lineModel.py and fitting.py in favor of using linear regression, perhaps from bumps, directly in fitDialog. Also could clean up what looks like dead code?
Change History (1)
comment:1 Changed 7 years ago by butler
- Milestone changed from SasView Next Release +1 to SasView 5.0.0