Opened 9 years ago
Last modified 7 years ago
#489 closed defect
ABS reader (NIST 1D) does not handle negative dx properly (USANS slit smearing) — at Version 1
Reported by: | pkienzle | Owned by: | |
---|---|---|---|
Priority: | critical | Milestone: | SasView 4.2.0 |
Component: | SasView | Keywords: | |
Cc: | Work Package: | SasView Bug Fixing |
Description (last modified by butler)
The NIST (*.ABS) USANS files contain the slit length as a negative entry in the dx column which is not recognized by the reader. Need to add the case of dx < 0 then dx =NONE and dl = abs(dx).
Change History (2)
Changed 9 years ago by pkienzle
comment:1 Changed 9 years ago by butler
- Description modified (diff)
- Milestone changed from SasView Next Release +1 to SasView 4.0.0
- Summary changed from new reader for NIST Igor USANS format to ABS reader (NIST 1D) does not handle negative dx properly (USANS slit smearing)