Changes between Version 23 and Version 24 of DevNotes/Obsolete/v3p1PunchList


Ignore:
Timestamp:
Jun 30, 2015 11:34:57 AM (9 years ago)
Author:
butler
Comment:

Legend:

Unmodified
Added
Removed
Modified
  • DevNotes/Obsolete/v3p1PunchList

    v23 v24  
    1313  
    14143. I think, from experiment with data rather than looking at the code, the docs for the Hayter MSA structure factor needs to note that even if no salt has been specifically added to the sample,  the “salt conc” may need to be non-zero to allow for counterions that have come off say a micelle as it charges up. One day I will code up a version of the Hayter MSA where the Debye length is explicitly entered. NOTE added by PDB:  I'm not sure that is true.  The implication fromt the documentation (again without delving deeply into the code) is that the counterions are accounted for (assumed to be monovalent one per charge on colloid).  The documentation already indicates that currently the ionic strength cannot be directly entered and that the counterions and salts are all assumed mono-valent. 
    15 >'''TICKET FOR NEXT RELEASE''' 
     15>'''TICKET FOR NEXT RELEASE''' #439 
    1616  
    17174. The “help about” box does not report the exact build number, just has 1>