#760 | fixed | ordering of parameters in multiplication model P(Q)S(Q) | Paul Kienzle <pkienzle@… | richardh |
Description |
Would be very nice if parameter list for P(Q)S(Q) was not in alphabetic order but remained in the order for the individual models, with P(Q) appearing first, then S(Q). |
|||
#468 | fixed | Fit constraint "Remove" buttons broken | Paul Kienzle <pkienzle@…> | mathieu |
Description |
When setting up constrained/simultaneous fitting, the remove button doesn't apply to the correct line. It removes the parameter listed above the one you are pointing at. |
|||
#474 | fixed | slit smearing is broken in 3.1 | Paul Kienzle <pkienzle@…> | pkienzle |
Description |
I'm following up on our conversation earlier about the smearing in sasview 3.1.1. I noticed that the slit smearing in 3.1.1 had strange behavior at high-q - namely a sharp drop off at the highest q-values, but I didn't see this behavior in 3.0.0. To investigate this discrepancy, I calculated the unsmeared and slit smeared scattering intensity for the teubner-strey model with four independent pieces of code: Jan Ilavsky's software, sasview 3.0.0, sasview 3.1.1, and my own code. All codes reproduce the unsmeared intensity identically. Jan's code, my code, and sasview 3.0.0 smear the model nearly identically, but sasview 3.1.1 is far off. |