Changeset 280f929 in sasview
- Timestamp:
- Oct 5, 2016 8:41:59 PM (8 years ago)
- Branches:
- master, ESS_GUI, ESS_GUI_Docs, ESS_GUI_batch_fitting, ESS_GUI_bumps_abstraction, ESS_GUI_iss1116, ESS_GUI_iss879, ESS_GUI_iss959, ESS_GUI_opencl, ESS_GUI_ordering, ESS_GUI_sync_sascalc, costrafo411, magnetic_scatt, release-4.1.1, release-4.1.2, release-4.2.2, ticket-1009, ticket-1094-headless, ticket-1242-2d-resolution, ticket-1243, ticket-1249, ticket885, unittest-saveload
- Children:
- 3a22ce7
- Parents:
- ec860a8f
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
src/sas/sasgui/guiframe/media/data_formats_help.rst
rd85c194 r280f929 3 3 .. This is a port of the original SasView html help file to ReSTructured text 4 4 .. by S King, ISIS, during SasView CodeCamp-III in Feb 2015. 5 .. WG Bouwman, DUT, added during CodeCamp-V in Oct 2016 the SESANS data format 5 6 6 7 .. _Formats: … … 9 10 ============ 10 11 11 SasView reads several different 1D (I(Q) vs Q) and 2D (I(Qx,Qy) vs (Qx,Qy)) 12 SasView reads several different 1D (I(Q) vs Q), 2D SANS(I(Qx,Qy) vs (Qx,Qy)) 13 and SESANS (P(z) vs z) 12 14 data files. But please note that SasView does not at present load data where 13 15 the Q and I(Q) data are in separate files. 14 16 15 1D Formats 16 ---------- 17 1D Formats SANS 18 --------------- 17 19 18 20 SasView will read files with 2 to 4 columns of numbers in the following order: … … 46 48 .. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 47 49 48 2D Formats 49 ---------- 50 2D Formats SANS 51 --------------- 50 52 51 53 SasView will only read files in the NIST 2D format with the extensions … … 60 62 .. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 61 63 62 .. note:: This help document was last changed by Steve King, 01May2015 64 SESANS Format 65 ------------- 66 67 The current file extension is .ses or .sesans (not case sensitive). 68 69 The file format is to have a list of name-value pairs as a header at the top of the file, detailing general experimental parameters necessary for fitting and analyzing data. This list should contain all information necessary for the file to be 'portable' between users. 70 71 Following that is a 6 column list of instrument experimental variables: 72 73 - Spin echo length (z, in Angstroms) 74 - Spin echo length error (:math:`\Delta` z, in Angstroms) (experimental resolution) 75 - neutron wavelength (:math:`\lambda`, in Angstroms) (essential for ToF instruments) 76 - neutron wavelength error (:math:`\Delta \lambda`, in Angstroms) 77 - Normalized polarization (:math:`P/P_0`, unitless) 78 - Normalized polarization error (:math:`\Delta(P/P_0)`, unitless) (measurement error) 79 80 81 .. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 82 83 .. note:: This help document was last changed by Wim Bouwman, 05Oct2016
Note: See TracChangeset
for help on using the changeset viewer.