source: sasview/src/sas/perspectives/fitting/media/fitting_help.rst @ 26500ec

ESS_GUIESS_GUI_DocsESS_GUI_batch_fittingESS_GUI_bumps_abstractionESS_GUI_iss1116ESS_GUI_iss879ESS_GUI_iss959ESS_GUI_openclESS_GUI_orderingESS_GUI_sync_sascalccostrafo411magnetic_scattrelease-4.1.1release-4.1.2release-4.2.2release_4.0.1ticket-1009ticket-1094-headlessticket-1242-2d-resolutionticket-1243ticket-1249ticket885unittest-saveload
Last change on this file since 26500ec was 98b30b4, checked in by smk78, 10 years ago

Dupilicate links resolved

  • Property mode set to 100644
File size: 27.0 KB

Fitting Perspective

Load_a_File

Single_Fit

Simultaneous_Fitting

Batch_Fitting

Model_Selection

Model_Category_Manager

Model_Functions

Custom_Model_Editor

Polydispersity_Distributions

Smearing_Computation

Polarisation_Magnetic_Scattering

Key_Combinations

Status_Bar_Help

Load a File

From Menu go to Data -> Load Data File(or Folder) . Select a file/folder from the menu bar and click on Open button. Data contained in the file will be displayed. To cancel the loading click on cancel . In case a file can not be loaded, an error message will be displayed on the statusbar.

Single Fit

One of two fit-engines can be chosen from the Fitting menu bar. The Simple Fit- engine uses Scipy's leasqr and the Complex Fit-Engine is a custom optimizer that provides a better chance to find the global minimum of the χ 2 but that requires longer computation time. In order to set a data to a control panel (FitPage), see the "DataLoader Help". Once a data set to the FiPage, select a model from the combo box. The default parameters of the model will be display. Set initial parameters if need. Check and uncheck parameters to fit/fix. Click the 'Fit' button. When the fitting is finished, the resultant parameter values will be displayed with the errors. If a error is missing, it generally means that the corresponding parameter is not very depending on the model. The chisq/Npt_fit and the plot associated with the fit operation will be also updated.

Simultaneous Fitting

This fitting option enables to set a number of the constraints between the parameters of fitting(s). It requires one or more FitPages with a data and a model set for the fitting, and performs multiple fittings given by the FitPage(s). The Complex (ParkMC) FitEngine will be used automatically.

Simultaneous Fit without Constraint

Assuming some FitPages are already set up, check the checkboxes of the model_data rows to fit. And click the 'Fit' button. The results will return to each FitPages.

Note that the chi2/Npts returned is the sum of the chi2/Npts of each fits. If one needs the chi2 value only for a page, click the 'Compute' button in the FitPage to recalculate.

Simultaneous Fit with Constraint

Enter constraint in the text control next to constraint fit button. Constraint should be of type model1 parameter name = f(model2 parameter name) for example, M0.radius=2*M1.radius. Many constraints can be entered for a single fit. Each of them should be separated by a newline charater or ";" The easy setup can generate many constraint inputs easily when the selected two models are the same type.

Note that the chi2/Npts returned is the sum of the chi2/Npts of each fits. If one needs the chi2 value only for one fit, click the 'Compute' button in the FitPage to recalculate.

Batch Fit

Create a Batch Page by selecting the Batch radio button on the DataExplorer (see figure below) and for a new control page select 'New FitPage' in the Fitting menubar.

batch_button_area.bmp

Figure 1: MenuBar:

Load Data to the DataExplorer if not already loaded.

Select one or more data sets by checking the check boxes, and then make sure that "Fitting" is selected in the dropdown menu next to the "Send To" button. Once ready, click the 'Send To' button to set data to a BatchPage. If already an empty batch page exists, it will be set there. Otherwise it will create a new Batch Page. Set up the model and the parameter values as same as a single fitting (see Single Fit help) <Single_Fit>. Then use 'Fit' button to perform the fitting.

Unlike a single fit, the results of the fittings will not return to the BatchPage'. Instead, a Grid window will be provided once the fitting is completed. The Grid window is also accessible from the 'View' menu (see Figure 2).

Note that only one model is used for all the data. The initial parameter values given in the control page will be used all the data fittings. If one wants the FitEngine to use the initial values from the results of the previous data fitting (if any), choose the 'Chain Fitting' option in the Fitting menubar, which will speed up the fitting especially when you have lots of, and similar, data sets.

Batch Window

Batch Window provides an easy way to view the fit results, i.e., plot data, fits, and residuals. Batch window will be automatically shown after a batch fit is finished.

Once closed, it can be opened anytime from the "View" menubar item (see Figure 2).

restore_batch_window.bmp

Figure 2: Edit Menu:

Edit Grid

Once a batch fit is completed, all fitted and fixed model parameters are displayed to the current sheet of the batch window except the errors of the parameters. To view the errors, click on a given column then under Edit menubar item, and insert the desired parameter by selecting a menu item with the appropriated label. Empty column can be inserted in the same way. A column value can be customized by editing an existing empty column.

To Remove column from the grid, select it, choose edit menu, and click the 'remove' menu item. Any removed column should reinserted whenever needed.

All above options are also available when right clicking on a given column label(see Figure 3).

Note: A column always needs to be selected in order to remove or insert a column in the grid.

edit_menu.bmp

Figure 3: Edit Menu:

Save Grid

To save the current page on the batch window, select the 'File' menubar item(see Figure 4), then choose the 'Save as' menu item to save it as a .csv file.

Note: The grid doesn't save the data array, fits, and the array residuals. As a result, the 'View (fit) Results' functionality will be lost when reloading the saved file.

Warning! To ensure accuracy of saved fit results, it is recommended to save the current grid before modifying it .

Open Batch Results

Any csv file can be opened in the grid by selecting the 'Open' under the 'File' menu in the Grid Window(see Figure 4). All columns in the file will be displayed but insertion will not available. Insertion will be available only when at least one column will be removed from the grid.

file_menu.bmp

Figure 4: MenuBar:

Plot

To plot a column versus another, select one column at the time, click the 'Add' button next to the text control of X/Y -axis Selection Range to plot the value of this column on the X/Y axis. Alternatively, all available range can be selected by clicking the column letter (eg. B). Repeat the same procedure the next axis. Finally, click the 'Plot' button. When clicking on Add button, the grid will automatically fill the axis label, but different labels and units can be entered in the correct controls before clicking on the plot button.

X/Y -Axis Selection Range can be edited manually. These text controls allow the following types of expression (operation can be + - * /, or pow)

1) if the current axis label range is a function of 1 or more columns, write this type of expression

constant1 * column_name1 [minimum row index : maximum row index] operator constant2 * column_name2 [minimum row index : maximum row index]

Example: radius [2 : 5] -3 * scale [2 : 5]

2) if only some values of a given column are need but the range between the first row and the last row used is not continuous, write the following expression in the text control

column_name1 [minimum row index1 : maximum row index1] , column_name1 [minimum row index2 : maximum row index2]

Example : radius [2 : 5] , radius [10 : 25]

Note: Both text controls ( X and Y-axis Selection Ranges) need to be filled with valid entries for plotting to work. The dY-bar is optional (see Figure 5).

plot_button.bmp

Figure 5: Plotting

View Column/Cell(s)

Select 1 or more cells from the same column, click the 'View Fits' button to display available curves.

For example, select the cells of the 'Chi2' column, then click the 'View Fits' button. The plots generates will represent the residuals plots.

If you select any cells of the 'Data' column and click the 'View Fits' button. It generates both data and fits in the graph (see Figure 6).

Alternatively, just click the column letter (eg. B) to choose all the available data sets, then simply click the 'View Fits' button to plot the data and fits.

view_button.bmp

Figure 6: View Fits

Model_Type

Change_Model_Parameters

Write_your_Own_Model

Model Type

Models are grouped into three classes

  • Shapes
  • Shape-Independent
  • Uncategorised
  • Customized Models
  • Structure Factor

Change Model Parameters

To visualize model in a different window, from menu click on Model. Select a type of model and then the name of your model.A new window will appear with the plot of your model with default values. Change model's parameters on model view tab and view the plotted model with its new parameters.

Write your Own Model

The custom model editors are provided from 'Fitting' menu in the menu bar. See 'Custom model editor' in the side menu on left. Advanced users can write your own model and save it (in .py format) into plugin_models directory in .sasview of your home directory (eg., username.sasview>plugin_models). Your plugin model will be added into "<>Customized Models" on the next model selection.

Model Category Manager

Our SAS models are, by default, classified into 5 categories; shapes, shape-independent, structure factor, and customized models, where these categories (except the customized models) can be reassigned, added, and removed using 'Category Manager'. Each models can also be enabled(shown)/ disabled(hidden) from the category that they belong. The Category Manager panel is accessible from the model category 'Modify' button in the fitting panel or the 'View/Category Manager' menu in the menu bar (Fig. 1).

1) Enable/Disable models: Check/uncheck the check boxes to enable/disable the models (Fig. 2).

2) Change category: Highlight a model in the list by left-clicking and click the 'Modify' button. In the 'Change Category' panel, one can create/use a category for the model, then click the 'Add' button. In order to delete a category, select a category name and click the 'Remove Selected' button (Fig. 3).

3) To apply the changes made, hit the OK button. Otherwise, click the 'Cancel' button (Fig. 2).

cat_fig0.bmp

Fig.1

cat_fig1.bmp

Fig.2

cat_fig2.bmp

Fig.3

Model Functions

Model Documentation <models/model_functions>

Description

This menu (Fitting/Edit Custom Model in the menu bar) interface is to provide you an easy way to write your own custom models. The changes in a model function are effective after it is re-selected from the combo-box menu.

edit_model_menu.bmp

New

This option is used to make a new model. A model code generated by this option can be viewed and further modified by the 'Advanced' option below.

new_model.bmp

Sum|Multi(p1,p2)

This option create a new sum (or multiplication) model. Fill up the (sum model function) name and the description. The description will show up on details button in the application. Then select the p1 or p2 model for the sum/multi model, select an operator as necessary and click the Apply button for activation. Hit the 'Close' button when it's done.

sum_model.bmp

Advanced

The menu option shows all the files in the plugin_models folder. You can edit, modify, and save it. It is recommended to modify only the lines with arrow (-------). In the end of edit, 'Compile' and 'Run' from the menu bar to activate or to see the model working properly.

Delete

The menu option is to delete the custom models. Just select the file name to delete.

Polydispersity Distributions

Calculates the form factor for a polydisperse and/or angular population of particles with uniform scattering length density. The resultant form factor is normalized by the average particle volume such that

P(q) = scale*<F*F>/Vol + bkg

where F is the scattering amplitude and the<>denote an average over the size distribution. Users should use PD (polydispersity: this definition is different from the typical definition in polymer science) for a size distribution and Sigma for an angular distribution (see below).

Note that this computation is very time intensive thus applying polydispersion/ angular distrubtion for more than one paramters or increasing Npts values might need extensive patience to complete the computation. Also note that even though it is time consuming, it is safer to have larger values of Npts and Nsigmas.

The following five distribution functions are provided

  • Rectangular_Distribution_
  • Array_Distribution_
  • Gaussian_Distribution_
  • Lognormal_Distribution_
  • Schulz_Distribution_

Rectangular Distribution

pd_image001.png

The xmean is the mean of the distribution, w is the half-width, and Norm is a normalization factor which is determined during the numerical calculation. Note that the Sigma and the half width w are different.

The standard deviation is

pd_image002.png

The PD (polydispersity) is

pd_image003.png pd_image004.jpg

Array Distribution

This distribution is to be given by users as a txt file where the array should be defined by two columns in the order of x and f(x) values. The f(x) will be normalized by SasView during the computation.

Example of an array in the file

30 0.1 32 0.3 35 0.4 36 0.5 37 0.6 39 0.7 41 0.9

We use only these array values in the computation, therefore the mean value given in the control panel, for example ‘radius = 60’, will be ignored.

Gaussian Distribution

pd_image005.png

The xmean is the mean of the distribution and Norm is a normalization factor which is determined during the numerical calculation.

The PD (polydispersity) is

pd_image003.png pd_image006.jpg

Lognormal Distribution

pd_image007.png

The /mu/=ln(xmed), xmed is the median value of the distribution, and Norm is a normalization factor which will be determined during the numerical calculation. The median value is the value given in the size parameter in the control panel, for example, “radius = 60â€ᅵ.

The PD (polydispersity) is given by /sigma/

pd_image008.png

For the angular distribution

pd_image009.png

The mean value is given by xmean=exp(/mu/+p2/2). The peak value is given by xpeak=exp(/mu/-p2).

pd_image010.jpg

This distribution function spreads more and the peak shifts to the left as the p increases, requiring higher values of Nsigmas and Npts.

Schulz Distribution

pd_image011.png

The xmean is the mean of the distribution and Norm is a normalization factor which is determined during the numerical calculation.

The z = 1/p2– 1.

The PD (polydispersity) is

pd_image012.png

Note that the higher PD (polydispersity) might need higher values of Npts and Nsigmas. For example, at PD = 0.7 and radisus = 60 A, Npts >= 160, and Nsigmas >= 15 at least.

pd_image013.jpg

Slit Smearing

The sit smeared scattering intensity for SAS is defined by

sm_image002.gif

where Norm =

sm_image003.gif

Equation 1

The functions inlineimage004 and inlineimage005 refer to the slit width weighting function and the slit height weighting determined at the q point, respectively. Here, we assumes that the weighting function is described by a rectangular function, i.e.,

sm_image006.gif

Equation 2

and

sm_image007.gif

Equation 3

so that inlineimage008 inlineimage009 for inlineimage010 and u.

The inlineimage011 and inlineimage012 stand for the slit height (FWHM/2) and the slit width (FWHM/2) in the q space. Now the integral of Equation 1 is simplified to

sm_image013.gif

Equation 4

Numerical Implementation of Equation 4

Case 1

For inlineimage012 = 0 and inlineimage011 = constant.

sm_image016.gif

For discrete q values, at the q values from the data points and at the q values extended up to qN= qi + inlineimage011 the smeared intensity can be calculated approximately

sm_image017.gif

Equation 5

inlineimage018 = 0 for Is in j < i or j > N-1*.

Case 2

For inlineimage012 = constant and inlineimage011 = 0.

Similarly to Case 1, we get

inlineimage019 for qp= qi- inlineimage012 and qN= qi+ inlineimage012. inlineimage018 = 0 for Is in j < p or j > N-1.

Case 3

For inlineimage011 = constant and inlineimage011 = constant.

In this case, the best way is to perform the integration, Equation 1, numerically for both slit height and width. However, the numerical integration is not correct enough unless given a large number of iteration, say at least 10000 by 10000 for each element of the matrix, W, which will take minutes and minutes to finish the calculation for a set of typical SAS data. An alternative way which is correct for slit width << slit hight, is used in SasView. This method is a mixed method that combines method 1 with the numerical integration for the slit width.

sm_image020.gif

Equation 7

for qp= qi- inlineimage012 and qN= qi+ inlineimage012. inlineimage018 = 0 for Is in j < p or j > N-1.

Pinhole Smearing

The pinhole smearing computation is done similar to the case above except that the weight function used is the Gaussian function, so that the Equation 6 for this case becomes

sm_image021.gif

Equation 8

For all the cases above, the weighting matrix W is calculated when the smearing is called at the first time, and it includes the ~ 60 q values (finely binned evenly) below (>0) and above the q range of data in order to cover all data points of the smearing computation for a given model and for a given slit size. The Norm factor is found numerically with the weighting matrix, and considered on Is computation.

2D Smearing

The 2D smearing computation is done similar to the 1D pinhole smearing above except that the weight function used was the 2D elliptical Gaussian function

sm_image022.gif

Equation 9

In Equation 9, x0 = qcos/theta/ and y0 = qsin/theta/, and the primed axes are in the coordinate rotated by an angle /theta/ around the z-axis (below) so that x’0= x0cos/theta/+y0sin/theta/ and y’0= -x0sin/theta/+y0cos/theta/.

Note that the rotation angle is zero for x-y symmetric elliptical Gaussian distribution. The A is a normalization factor.

sm_image023.gif

Now we consider a numerical integration where each bins in /theta/ and R are evenly (this is to simplify the equation below) distributed by /delta//theta/ and /delta/R, respectively, and it is assumed that I(x’, y’) is constant within the bins which in turn becomes

sm_image024.gif

Equation 10

Since we have found the weighting factor on each bin points, it is convenient to transform x’-y’ back to x-y coordinate (rotating it by -/theta/ around z axis). Then, for the polar symmetric smear

sm_image025.gif

Equation 11

where

sm_image026.gif

while for the x-y symmetric smear

sm_image027.gif

Equation 12

where

sm_image028.gif

Here, the current version of the SasView uses Equation 11 for 2D smearing assuming that all the Gaussian weighting functions are aligned in the polar coordinate.

In the control panel, the higher accuracy indicates more and finer binnng points so that it costs more in time.

Polarisation/Magnetic Scattering

Magnetic scattering is implemented in five (2D) models

  • SphereModel
  • CoreShellModel
  • CoreMultiShellModel
  • CylinderModel
  • ParallelepipedModel

In general, the scattering length density (SLD) in each regions where the SLD (=/beta/) is uniform, is a combination of the nuclear and magnetic SLDs and depends on the spin states of the neutrons as follows. For magnetic scattering, only the magnetization component, M*perp, perpendicular to the scattering vector *Q contributes to the the magnetic scattering length.

mag_vector.bmp

The magnetic scattering length density is then

dm_eq.gif

where /gamma/ = -1.913 the gyromagnetic ratio, /mu/B is the Bohr magneton, r0 is the classical radius of electron, and /sigma/ is the Pauli spin. For polarised neutron, the magnetic scattering is depending on the spin states.

Let's consider that the incident neutrons are polarized parallel (+)/ anti-parallel (-) to the x' axis (See both Figures above). The possible out-coming states then are + and - states for both incident states

Non-spin flips: (+ +) and (- -) Spin flips: (+ -) and (- +)

M_angles_pic.bmp

Now, let's assume that the angles of the Q vector and the spin-axis (x') against x-axis are /phi/ and /theta/up, respectively (See Figure above). Then, depending upon the polarisation (spin) state of neutrons, the scattering length densities, including the nuclear scattering length density (/beta/N) are given as, for non-spin-flips

sld1.gif

for spin-flips

sld2.gif

where

mxp.gif myp.gif mzp.gif mqx.gif mqy.gif

Here, the M0x, M0y and M0z are the x, y and z components of the magnetization vector given in the xyz lab frame. The angles of the magnetization, /theta/M and /phi/M as defined in the Figure (above)

m0x_eq.gif m0y_eq.gif m0z_eq.gif

The user input parameters are M0_sld = DMM0, Up_theta = /theta/up, M_theta = /theta/M, and M_phi = /phi/M. The 'Up_frac_i' and 'Up_frac_f' are the ratio

(spin up)/(spin up + spin down)

neutrons before the sample and at the analyzer, respectively.

Note: The values of the 'Up_frac_i' and 'Up_frac_f' must be in the range between 0 and 1.

Copy & Paste

To copy the parameter values in a Fit(Model) panel to the clipboard:

Ctrl(Cmd on MAC) + Left(Mouse)Click on the panel.

To paste the parameter values to a Fit(Model)panel from the clipboard:

Ctrl(Cmd on MAC) + Shift + Left(Mouse)Click on the panel.

If this operation is successful, it will say so in the info line at the bottom of the SasView window.

Bookmark

Bookmark of a fit-panel or model-panel status:

(Mouse)Right-Click and select the bookmark in the popup list.

Graph Context Menu

To get the graph context menu to print, copy, save data, (2D)average, etc.:

Locate the mouse point on the plot to highlight and *(Mouse) Right Click to bring up the full menu.

FTolerance (SciPy)

To change the ftol value of the Scipy FitEngine (leastsq):

First, make sure that the Fit panel has data and a model selected.

Ctrl(Cmd on MAC) + Shift + Alt + Right(Mouse)Click on the panel.

Then, set up the value in the dialog panel.

If this operation is successful, the new ftol value will be displayed in the info line at the bottom of the SV window.Note that increasing the ftol value may cause for the fitting to terminate with higher χ sq.

Status Bar Help

Message_Warning_Hint

Console

Message/Warning/Hint

The status bar located at the bottom of the application frame, displays messages, hints, warnings and errors.

Console

Select light bulb/info icon button in the status bar at the bottom of the application window to display available history. During a long task, the console can also help users to understand the status in progressing.

Note: See TracBrowser for help on using the repository browser.