Custom Query (780 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (1 - 3 of 780)

1 2 3 4 5 6 7 8 9 10 11
Ticket Resolution Summary Owner Reporter
#929 fixed Problem deleting data in first fit page krzywon Adamo
Description

If send data to FitPage1 and then try to delete it, the FitPage1 deletes and "points" to FitPage2. As soon as you send other data to Fitting, the following error appears:

Fitting set_data: in method 'AuiNotebook_GetPageIndex', expected argument 2 of type 'wxWindow *'

#261 fixed Default number of bins in Phi average is not ideal Adrian Rennie
Description

20 is a poor default choice as it gives 18 degree bins. Something that was divisible by 4 and 6 would be better (most likely symmetries). Thus 36 would probably be good, but that may be too fine a division for most data. 18 is a good compromise - 20 degree bins including bins centered on 0, 90, 180 and 270 degrees.

#850 fixed Custom pinhole smearing is broken? krzywon Federica Sebastiani
Description

Federica Sebastian - student at LU noticed a problem with the custom smearing in SasView? 4.0.1 …

Setting values in custom pinhole smearing gives a different answer to loading the same values from a data file.

Some instruments do not provide resolution information - hence the need for the custom smearing.

Taking data set and calculating a, say, 8% dQ/Q and putting that in the file as the 4th column behaves as expected.

Generating a custom pinhole smear with *the same dQ_low and dQ_high* as the dataset with "fake" resolution column gives a completely different answer and blows the curve out.

Attached images are for the attached data set with (a) resolution from dQ data which was faked in the file. (b) resolution from a custom pinhole smear using the same dQ_low and dQ_high

1 2 3 4 5 6 7 8 9 10 11
Note: See TracQuery for help on using queries.