Ignore:
Timestamp:
Feb 14, 2015 12:12:40 PM (9 years ago)
Author:
smk78
Branches:
master, ESS_GUI, ESS_GUI_Docs, ESS_GUI_batch_fitting, ESS_GUI_bumps_abstraction, ESS_GUI_iss1116, ESS_GUI_iss879, ESS_GUI_iss959, ESS_GUI_opencl, ESS_GUI_ordering, ESS_GUI_sync_sascalc, costrafo411, magnetic_scatt, release-4.1.1, release-4.1.2, release-4.2.2, release_4.0.1, ticket-1009, ticket-1094-headless, ticket-1242-2d-resolution, ticket-1243, ticket-1249, ticket885, unittest-saveload
Children:
898a8b9
Parents:
3e2ebbb
Message:

Level 1 sphinx-ready commit of remaining help files

File:
1 edited

Legend:

Unmodified
Added
Removed
  • src/sas/guiframe/media/data_explorer_help.rst

    r3e2ebbb r78f02c3  
    11.. _data_explorer_help.rst 
     2 
     3.. This is a port of the original SasView html help file to ReSTructured text 
     4.. by S King, ISIS, during SasView CodeCamp-III in Feb 2015. 
    25 
    36Loading Data 
    47============ 
    58 
    6 Introduction_  
    7 Load data_ 
    8 Handy menu_ 
    9 Activate data_ 
    10 Remove data_ 
    11 Append plot to graph_ 
    12 Create new plot_ 
    13 Freeze theory_ 
    14 Send data to applications_ 
     91. Introduction_  
     102. Load Data_ 
     113. Handy Menu_ 
     124. Activate Data_ 
     135. Remove Data_ 
     146. Append Plot to Graph_ 
     157. Create New Plot_ 
     168. Freeze Theory_ 
     179. Send Data to Applications_ 
    1518 
    16 .. _Introduction :  
    17 ------------------ 
    18 *Data Explorer*  is a panel that allows the user more interactions with data. Some functionalities provided by the Data Explorer are also available through the context menu of plot panels or other menus of the applications.Under menu *View*  of the menubar, Data explorer can be toggled between Show and Hide by clicking the menu *Show/Hide Data Explorer* . 
     19.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
    1920 
    20 *IMPORTANT!*  When Data explorer is hidden, all the data loaded will be sent directly to the current active application, if possible. When data Explorer is shown data go first to the Data Explorer for the user to handle them later. 
     21.. _Introduction: 
    2122 
    22 .. _Load data :  
    23 --------------- 
    24 To Load data, click the button *Load Data* , then select one or more (holding Ctrl key) files to load into the application. In the list, the *Data*  will be displayed as the name of each selected file. Expending this data by clicking the *+*  symbol will display available information about the data such as data title if exists. 
     23Introduction 
     24------------ 
     25*Data Explorer* is a panel that allows the user more interactions with data.  
     26Some functionalities provided by the Data Explorer are also available through  
     27the context menu of plot panels or other menus of the applications.Under menu  
     28*View*  of the menubar, Data explorer can be toggled between Show and Hide by  
     29clicking the menu *Show/Hide Data Explorer* . 
    2530 
    26 .. _Handy menu :  
    27 ---------------- 
    28 For a quick Data-info/Save/Plot/3d-plot(2d only)/Edit-mask(2d only), high-light the data/theory, right-click, and select a proper item from the context menu. 
     31*IMPORTANT!*  When Data explorer is hidden, all the data loaded will be sent  
     32directly to the current active application, if possible. When data Explorer is  
     33shown data go first to the Data Explorer for the user to handle them later. 
     34 
     35.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     36 
     37.. _Load Data: 
     38 
     39Load Data 
     40--------- 
     41 
     42To Load data, click the button *Load Data* , then select one or more (holding  
     43Ctrl key) files to load into the application. In the list, the *Data*  will be  
     44displayed as the name of each selected file. Expending this data by clicking  
     45the *+*  symbol will display available information about the data such as data  
     46title if exists. 
     47 
     48.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     49 
     50.. _Handy Menu: 
     51 
     52Handy Menu 
     53---------- 
     54 
     55For a quick Data-info/Save/Plot/3d-plot(2d only)/Edit-mask(2d only),  
     56high-light the data/theory, right-click, and select a proper item from the  
     57context menu. 
     58 
    2959.. _ image:: hand_menu.png 
    3060 
     61.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
    3162 
    32 .. _Activate data :  
    33 ------------------- 
    34 To interact with data, check a data label and click on a button. Checking Data make them active for the button operation. Unchecking Data labels will deactivate them. 
     63.. _Activate Data: 
    3564 
    36 There is a combo box labeled *Selection Options*  that allows to activate or select multiple data simultaneously. 
     65Activate Data 
     66------------- 
    3767 
    38 .. _Remove data :  
    39 ----------------- 
     68To interact with data, check a data label and click on a button. Checking Data  
     69make them active for the button operation. Unchecking Data labels will  
     70deactivate them. 
     71 
     72There is a combo box labeled *Selection Options*  that allows to activate or  
     73select multiple data simultaneously. 
     74 
     75.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     76 
     77.. _Remove Data: 
     78 
     79Remove Data 
     80----------- 
     81 
    4082Remove data button remove all reference of this data into the application. 
    4183 
    4284*WARNING!* Remove data will stop any jobs currently using the selected data. 
    4385 
    44 .. _Append plot to graph :  
    45 -------------------------- 
    46 Click on the button *Append To*  to append selected Data to a plot panel on focus. Next to this button is a combo box containing available panels names. Selecting a name from this combo box will set the corresponding lot panel on focus. If not plot panel is available, the combo box and button will be disable. 2D Data cannot be appended to any plot panels . This operation can only be performed on 1D data and plot panels currently containing 1D data. 
     86.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
    4787 
    48 .. _Create new plot :  
    49 --------------------- 
    50 Click on *New Plot*  button to create a new plot panel where selected data will be plotted. 
     88.. _Append Plot to Graph: 
    5189 
    52 .. _Freeze theory :  
     90Append Plot to Graph 
     91-------------------- 
     92 
     93Click on the button *Append To*  to append selected Data to a plot panel on  
     94focus. Next to this button is a combo box containing available panels names.  
     95Selecting a name from this combo box will set the corresponding lot panel on  
     96focus. If not plot panel is available, the combo box and button will be  
     97disable. 2D Data cannot be appended to any plot panels . This operation can  
     98only be performed on 1D data and plot panels currently containing 1D data. 
     99 
     100.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     101 
     102.. _Create New Plot: 
     103 
     104Create New Plot 
     105--------------- 
     106 
     107Click on *New Plot*  button to create a new plot panel where selected data  
     108will be plotted. 
     109 
     110.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     111 
     112.. _Freeze Theory: 
     113 
     114Freeze Theory 
     115------------- 
     116 
     117*Freeze Theory*  button generate Data from selected theory. This operation can  
     118only be performed when theory labels are selected. 
     119 
     120.. ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ 
     121 
     122.. _Send to application: 
     123 
     124Send to Application 
    53125------------------- 
    54 *Freeze Theory*  button generate Data from selected theory. This operation can only be performed when theory labels are selected. 
    55126 
    56 .. _Send to application :  
    57 ------------------------- 
    58 Click on the button *Send To*  to send Data to the current active control page. One of the single/batch mode can be selected only for Fitting. The batch mode provides serial (batch) fitting with one model, i.e., fitting one data by another data. Note that only the Fitting allows more that one data to be sent. 
    59  
     127Click on the button *Send To*  to send Data to the current active control  
     128page. One of the single/batch mode can be selected only for Fitting. The batch  
     129mode provides serial (batch) fitting with one model, i.e., fitting one data by  
     130another data. Note that only the Fitting allows more that one data to be sent. 
Note: See TracChangeset for help on using the changeset viewer.